Compact Diesel Light Tower — ZLTW550
6 kW / 6 kVA · 4.5 m telescopic mast · 104,000 lumens · 390 kg · 40 units per 40'HQ
A single-cylinder air-cooled genset, four 200 W LED floodlights and a three-section telescopic mast on a 390 kg towable chassis. Built for rental fleets that need light fast, and for sites that cannot wait for a truck-mounted tower.

QUICK ANSWER
The ZLTW550 is a compact diesel light tower: a 6 kW silent genset drives four 200 W LED floodlights mounted on a 4.5 m three-section telescopic mast, all carried on a 390 kg four-wheel chassis with a 15 L tank that runs about 10 hours. It is aimed at rental fleets, road works, security perimeters, event sites and remote camps where a full-size 9 m tower is more machine than the job needs — and where 40 units fitting into a single 40’HQ container is the number that decides the landed cost.
SECTION 01 What the ZLTW550 Is, and Where It Fits
Most light towers on the market are sized for highway construction: 9 m masts, 1,500 kg trailers, four 1,000 W lamps and a 10 kVA genset. They are excellent at that job and over-specified for almost every other one. A rental company sending a tower to a car park resurfacing job, a weekend festival or a temporary security post does not need 9 m of mast — it needs a machine one person can tow, set up in four minutes and recover the next morning.
The ZLTW550 is built around that narrower brief. The mast stops at 4.5 m in three sections, lifted by a manual winch rather than hydraulics, which removes the single most common failure point on rental towers. The lighting array is four 200 W LED floodlights at 26,000 lumens each, giving 104,000 lumens in total from 800 W of load — roughly the same site illumination as a 4 × 1,000 W halogen tower while drawing a fifth of the power.
Because the whole machine weighs 390 kg and stands 1,250 × 800 × 1,100 mm, container economics change completely: 20 units load into a 20’GP and 40 units into a 40’HQ. For a distributor buying a fleet, that is the difference between three shipments and one.
Typical applications
|
APPLICATION
|
WHY THIS MODEL SUITS IT
|
|
Rental fleet
|
390 kg tows behind a pickup, manual mast means fewer hydraulic service calls, 10 h runtime covers a night shift without refuelling.
|
|
Road and utility works
|
4.5 m mast clears a trench line and a small excavator; four-point support keeps the light steady on broken asphalt.
|
|
Event and site lighting
|
Low-glare LED array on a 360° rotating mast, quiet enough for a residential setting at night.
|
|
Security and perimeter
|
Sets up in minutes at a gate or yard corner; amber warning beacon on the canopy for plant-yard visibility.
|
|
Mining and remote camps
|
Air-cooled single-cylinder engine needs no coolant, no radiator and no water supply — one less consumable on site.
|
SECTION 02 The Diesel Generator Set: 6 kW in a Silent Canopy
The power core is a 6 kW / 6 kVA single-phase genset, packaged inside a powder-coated steel canopy with a louvred air outlet and a hinged service door. The canopy does two jobs: it drops the operating noise to a level that does not carry across a residential street at night, and it keeps rain and site dust out of the alternator and control gear.
|
GENERATOR SET
|
SPECIFICATION
|
|
Rated output
|
6 kW / 6 kVA
|
|
Frequency
|
50 Hz / 60 Hz
|
|
Voltage
|
110–270 V available
|
|
Power factor
|
1.0
|
|
Phase
|
Single phase, 220 V AC output
|
|
Starting mode
|
Electric start, 12 V battery
|
|
Control panel
|
SmartGen controller with digital hour meter and live monitoring
|
|
Panel protection
|
IP65
|

The control panel is deliberately simple. A SmartGen module with a digital hour meter, start/stop, and live monitoring of voltage, frequency and runtime is all a rental tower needs — and all the operator will actually use at 2 a.m. Complex paralleling or remote-SCADA functions belong on prime-power gensets, not on a machine that gets towed between twelve sites a month.
SECTION 03 The Diesel Engine: Single-Cylinder, Air-Cooled, 188 Platform
The engine is the ZTA POWER 188 — a single-cylinder, four-stroke, air-cooled diesel running at 3,600 rpm. Air cooling is the defining choice here: no radiator, no coolant hoses, no water pump and no freeze protection. On a machine that may sit unused for weeks and then be started in a coastal yard or a desert camp, removing the cooling circuit removes the most common cause of field failure.
|
ENGINE
|
SPECIFICATION
|
|
Brand / model
|
ZTA POWER 188
|
|
Type
|
Single-cylinder, four-stroke diesel
|
|
Cooling
|
Air-cooled (forced air, no coolant)
|
|
Rated speed
|
3,600 rpm
|
|
Bore × stroke
|
88 × 90 mm
|
|
Starting
|
Electric start, 12 V battery
|
|
Fuel
|
Diesel, 15 L integral tank
|
|
Running time
|
Approximately 10 hours per tank
|
What 3,600 rpm means for the buyer
A 3,600 rpm single is lighter and cheaper than a 1,500 rpm water-cooled set of the same output, which is why compact towers use it. The trade-off is service interval: valve clearance, oil and the air filter element need attention on a tighter schedule than a slow-speed industrial engine. We state this openly because rental customers who understand the interval get 5,000+ hours out of the platform, while those who treat it like a 1,500 rpm genset do not. The full maintenance schedule ships with every unit, and the service kit is listed in the spare-parts section of the manual.
SECTION 04 The Alternator: 5.5 kW Brush, Self-Excited
Behind the engine sits a 5.5 kW / 5.5 kVA single-phase alternator, brush type, self-excited, producing 220 V AC. Self-excitation means the machine builds its own voltage from residual magnetism — no separate excitation supply, no AVR board to fail, and field service is limited to checking brushes and bearings.
|
ALTERNATOR
|
SPECIFICATION
|
|
Rated output
|
5.5 kW / 5.5 kVA
|
|
Phase
|
Single phase
|
|
Output voltage
|
220 V AC (110–270 V range available on request)
|
|
Frequency
|
50 Hz / 60 Hz
|
|
Excitation
|
Brush, self-excited
|
|
Duty with lighting load
|
Continuous at rated LED load (800 W) with margin for the auxiliary outlet
|

Note the 5.5 kW alternator against a 6 kW engine rating: the engine carries headroom so the set absorbs the inrush of the LED drivers at switch-on and any aux tool plugged into the outlet, without dropping frequency enough to make the lamps flicker. That margin is deliberate, not a data-sheet inconsistency.
SECTION 05 Mast and Lighting System
The mast is the part customers underestimate. A 4.5 m three-section telescopic column with a manual winch lifts the light bar to working height in under a minute, rotates a full 360° on its base bearing, and locks at the chosen angle. Four support legs with screw jacks take the load off the tyres so the tower stays level on a slope or soft ground.
|
MAST & LIGHTING
|
SPECIFICATION
|
|
Max. height
|
4.5 m telescopic, rotating
|
|
Mast sections
|
3
|
|
Rotation
|
360°
|
|
Lifting system
|
Manual winch
|
|
Support points
|
4 (screw-jack stabilisers)
|
|
Floodlights
|
4 × LED, 200 W each
|
|
Luminous flux
|
4 × 26,000 lm = 104,000 lm total
|
|
Warning light
|
Amber beacon on canopy
|
Manual winch instead of hydraulics — a deliberate choice
Hydraulic masts raise faster and look more impressive in a brochure. They also introduce a pump, a cylinder, seals and oil — four failure modes that a rental fleet pays for repeatedly in the field. A manual winch with a self-locking brake has one moving assembly, can be serviced with hand tools, and never leaves a customer with a mast stuck at half height. For towers under 5 m, the weight penalty of hydraulics is not worth the reliability gain.
SECTION 06 Chassis, Dimensions and Transport
The chassis is a welded steel frame in the same orange powder coat as the canopy, carried on four pneumatic wheels with a height-adjustable drawbar and a jockey wheel. The machine can be towed behind a pickup or a light truck, winched onto a trailer bed, or lifted by forklift under the frame.
|
CHASSIS
|
SPECIFICATION
|
|
Overall dimensions
|
1,250 × 800 × 1,100 mm (transport position)
|
|
Weight (unfuelled)
|
390 kg
|
|
Wheels
|
4 pneumatic tyres, two axles
|
|
Drawbar
|
Adjustable height, with jockey wheel
|
|
Stabilisers
|
4 screw-jack support legs
|
|
Fuel tank
|
15 L integral, lockable filler
|
|
Finish
|
Powder-coated steel, orange (other colours on request)
|
SECTION 07 How the ZLTW550 Is Assembled: Eight Production Stages
Every unit passes these eight stages in sequence, in the same workshop, with a signed inspection record at each stage. The record travels with the machine and is available to the buyer on request.
1. Frame fabrication and welding Steel tube is cut on the CNC saw, jigged and MIG-welded into the chassis and mast base. Weld seams are dressed and inspected for porosity before the frame leaves the welding bay.
2. Shot blasting and powder coating Frame components are blasted to Sa 2.5, then coated in a two-stage process: zinc-rich primer and a 60–80 µm polyester powder topcoat, cured at 200 °C. Canopy panels are coated in the same batch so colour matches across the machine.
3. Canopy build and sound lining Panels, louvres, hinges, locks and the service door are assembled onto the base frame. Acoustic foam is bonded to the inner panels, and the exhaust is routed through a residential-grade silencer before the canopy is closed.
4. Engine and alternator coupling The 188 engine is bolted to the skid on anti-vibration mounts, the alternator is coupled through a flexible disc, and shaft alignment is checked with a dial gauge before the coupling guard goes on.
5. Fuel, exhaust and electrical routing The 15 L tank, fuel lines, filter and shut-off valve are fitted; the wiring harness is run in conduit with grommets at every panel penetration; the SmartGen controller, hour meter, breaker and battery isolator are mounted and terminated to the drawing.
6. Mast, light bar and lamp fitting The three mast sections are assembled with the winch and cable, the rotating base is shimmed for free movement, and the four LED floodlights are bolted to the cross bar with the wiring loomed and sealed at the junction box.
7. Load test and function test The set runs at 25%, 50%, 75% and 100% load on a resistive load bank. Voltage, frequency, oil pressure and exhaust temperature are recorded; the mast is raised and lowered three times, the lamps are switched in groups, and the warning beacon is checked.
8. Final inspection, labelling and packing Fastener torque is re-checked, touch-up paint applied, the rating plate and warning decals fitted, and the unit is photographed for the shipment file before protective wrapping and pallet fixing.
SECTION 08 Factory Equipment and Production Workflow
The ZLTW550 is built in ZTA Power’s own Xiamen workshop rather than sourced as a finished unit. Frame, canopy, assembly, wiring and testing all happen under one roof, which is why a colour change, a voltage change or a 60 Hz build is a production instruction rather than a new supply chain.
|
EQUIPMENT
|
WHAT IT DOES ON THIS PRODUCT
|
|
CNC fibre laser cutter
|
Cuts canopy panels, mast plates and brackets to ±0.1 mm, so panels fit without rework.
|
|
CNC press brake
|
Forms canopy and chassis sections; consistent bend radii keep door gaps even.
|
|
MIG welding stations with fixtures
|
Chassis and mast base welding on jigs, which keeps the four wheel mounts coplanar.
|
|
Shot-blasting booth
|
Surface preparation before powder coating; the step that decides whether paint survives a coastal site.
|
|
Powder coating line with curing oven
|
Primer plus topcoat, cured at 200 °C for adhesion and UV stability.
|
|
Resistive load bank (up to 2,000 kW)
|
Step-load testing of every genset, including the 6 kW set on this tower.
|
|
Fluke power analysers and tachometers
|
Records voltage, frequency, load and speed at each test step for the inspection file.
|
|
Overhead crane and forklift fleet
|
Handles canopy frames and finished towers; loads containers at the factory gate.
|
Production workflow, from order to vessel
1. Order review and drawing release Voltage, frequency, colour, plug type and labelling are confirmed against the PO, and the build sheet is released to the workshop.
2. Material and component kitting Steel, engines, alternators, controllers, lamps and fasteners are picked against the build sheet and staged per unit.
3. Fabrication and coating Cutting, bending, welding, blasting and powder coating — stages 1 and 2 of assembly.
4. Assembly line build Canopy, engine, alternator, wiring, mast and lamps fitted in sequence at fixed stations.
5. Testing and inspection Load bank run plus full function test; failed units return to the station, not to the packing area.
6. Packing and palletising Protective wrapping, desiccant, edge protection and pallet fixing, with the unit number recorded on the packing list.
7. Container loading and documentation Loading plan issued before the truck arrives; photos taken at each row; packing list, invoice and B/L draft checked against the load.
8. Shipping and after-sales file Documents released, warranty registered, and the unit’s test record filed against its serial number for future parts enquiries.
SECTION 09 Packing Details and Container Loading
Packing is where a 390 kg tower either arrives undamaged or arrives with a bent light bar. Each unit is wrapped in EPE foam at the lamp heads and mast joints, stretch-wrapped overall, edge-protected at the canopy corners and fixed to a plywood-topped pallet base. Batteries ship isolated, fuel tanks are drained, and the mast is locked in the fully retracted position with a travel strap.
|
PACKING & LOADING
|
DETAIL
|
|
Machine dimensions
|
1,250 × 800 × 1,100 mm (mast retracted, transport position)
|
|
Net weight
|
390 kg per unit (unfuelled)
|
|
Packing method
|
EPE foam at lamp heads and mast joints, stretch film, corner protection, plywood pallet base, steel strapping
|
|
Units per 20’GP
|
20 units
|
|
Units per 40’HQ
|
40 units
|
|
Loading pattern
|
Two rows, mast retracted and locked, drawbar folded where the container width allows
|
|
Shipping port
|
Xiamen, China
|
|
Lead time
|
Within 30 days after receipt of deposit
|
SECTION 10 Who Builds It: ZTA Power Factory Capability
Xiamen ZTA Power System Co., Ltd has been building generator sets and lighting towers for export since 2007, with Cummins, Perkins and Baudouin engines in the prime-power range and our own engine platform for compact equipment. Units ship to more than 200 countries, and the same workshop that assembles a 2,000 kVA containerised genset also builds this 390 kg tower.
[ Image 1 ] Factory exterior / workshop overview — replace with /uploads/zta-factory-overview.jpg
[ Image 2 ] Light tower assembly line — replace with /uploads/zta-light-tower-line.jpg
[ Image 3 ] Load bank test / container loading — replace with /uploads/zta-load-test.jpg
|
CAPABILITY
|
DETAIL
|
|
Experience
|
17+ years in generator set manufacturing and export
|
|
Export markets
|
200+ countries and regions
|
|
Product range
|
Diesel gensets 20 kW – 2,000 kVA, lighting towers, hybrid and reefer power
|
|
Engine partners
|
Cummins, Perkins, Baudouin, plus ZTA’s own compact engine platform
|
|
Testing
|
100% load bank test before packing, with recorded test sheet per unit
|
|
Quality system
|
ISO 9001; CE marking available for EU-bound units
|
|
Warranty
|
12 months or 1,000 running hours, whichever comes first
|
SECTION 11 Questions Buyers Ask Most
How many light towers fit in a 40ft container?
40 units in a 40’HQ and 20 units in a 20’GP, with the mast retracted and locked. The loading plan is issued before the truck arrives and photos are taken at each row.
How long does it run on one tank of fuel?
About 10 hours on the 15 L integral tank, driving the four 200 W LED floodlights. That covers a full night shift without refuelling, which is the figure rental customers actually plan around.
How much does a light tower like this weigh?
390 kg unfuelled — light enough to tow behind a pickup or a light truck, and light enough that two people can reposition it on a hard surface with the jockey wheel.
Is the mast hydraulic or manual?
Manual winch with a self-locking brake, on a three-section mast to 4.5 m. We chose manual deliberately: no pump, no cylinder, no seals, no oil — the four things that fail first on rental towers.
How bright is it, in practical terms?
104,000 lumens total from four 200 W LED floodlights (26,000 lm each). That is comparable site illumination to a 4 × 1,000 W halogen tower at roughly one fifth of the electrical load. IES photometric files are available if you need illuminance calculations.
Can it run 60 Hz and 110 V?
Yes. The set is built for 50 Hz or 60 Hz, and voltage is configurable across 110–270 V. Specify at order stage so the alternator and control settings are matched at build.
What engines do you use, and are parts available locally?
The ZLTW550 uses the ZTA POWER 188 single-cylinder air-cooled diesel. Consumables — filters, injector, starter, alternator brushes — are standard platform parts, and we hold spares for the model. Send us your market and we will confirm the nearest parts route.
Is the canopy weatherproof?
Yes. Powder-coated steel canopy with louvred ventilation and sealed panel joints, and the control panel is IP65 rated. The machine is designed for outdoor standing, not for submersion or monsoon flooding.
What is the warranty and lead time?
12 months or 1,000 running hours, whichever comes first, and delivery within 30 days after receipt of deposit for standard builds.
Can you private-label it for our rental brand?
Yes — canopy colour, decals, rating plate and manual branding can be changed at build stage. Minimum order for a custom colour run is one 20’GP.
SECTION 12 Request a Quotation
Send the table below filled in and we will come back with price, lead time and a loading plan. If you are comparing against another supplier, send their datasheet too — we will tell you honestly where this model is the wrong choice.
|
RFQ FIELD
|
PLEASE SPECIFY
|
|
Quantity
|
Units required (sample / 20’GP / 40’HQ)
|
|
Frequency & voltage
|
50 Hz or 60 Hz; 220 V / 230 V / 110 V; plug type
|
|
Canopy colour & branding
|
Standard orange or custom RAL; decals and rating plate
|
|
Destination port
|
Port of discharge and preferred Incoterm (EXW / FOB / CIF)
|
|
Compliance documents
|
CE, ISO 9001 test report, or any local import certificate
|
|
Spare parts
|
Filter kits, lamps, brushes, mast cable — quantity per unit
|
|
Delivery target
|
Required shipment window
|
|
Send one line: quantity + frequency + destination port.
We reply within 24 hours with EXW and FOB pricing, a loading plan and the current lead time. For markets where a larger mast is required, ask about our ZLTV5 towable light tower with 7.5 m mast; for fixed backup power, see our silent diesel generator sets.
Xiamen ZTA Power System Co., Ltd Room C5, No.113, Chengyi North Street, Software Park III, Torch High-tech Zone, Xiamen, China www.ztapower.com · nancy@ztapower.com
|