Why Does a Diesel Generator Cranks But Fails to Start?

Why Does a Diesel Generator Cranks But Fails to Start?

August 27, 2021

Why Does a Diesel Generator Cranks But Fails to Start?

Diesel generators are widely used due to their stable performance, reliable quality, and user-friendly operation. To ensure proper functioning, users must perform regular maintenance and be able to diagnose and troubleshoot common faults, thereby extending the generator’s service life and ensuring reliable backup power.

Prerequisites for Normal Diesel Generator Operation

For successful startup, two critical conditions must be met:

1.Properly atomized diesel fuel must be delivered precisely and timely into the combustion chamber. 

2.The compressed air in the combustion chamber must reach sufficient temperature for ignition.

If the diesel generator cranks but fails to start, possible causes should be investigated in the following areas:

Starting system 

Fuel supply system 

Compression issues

1. Diesel Generator Cranks But Won’t Start

(Compression is normal, but ignition fails)

Step-by-Step Diagnosis:

  • - Check Fuel Level – Verify the fuel gauge to ensure sufficient diesel supply.
  • - Inspect Fuel Filters & Lines – Clogged filters or blocked fuel lines can restrict fuel flow, preventing startup.

Common Causes of Fuel Delivery Failure:

Low-Pressure Fuel Circuit Issues

* Air leaks in fuel lines

* Weak fuel transfer pump (insufficient pressure)

* Blocked fuel lines 

* Incorrectly installed high-pressure pump (e.g., reversed inlet/return screws or low return pressure)

Throttle or Pump Malfunction

*Stuck plunger or throttle (preventing fuel delivery at startup position)

*Sudden mechanical failure (e.g., seized components)

Incorrect Fuel Injection Timing

* Newly calibrated pumps may be misaligned (too early/late injection)

* Worn timing advance mechanism ("timing drift" in older pumps)

Faulty Fuel Injection System

*Defective solenoid – Listen for a click when turning the ignition key.

*No click? → Solenoid or injection pump failure (replacement needed).

*Click but no fuel? → Pump failure (even if filters/lines are clear).

2. Diesel Generator Stalls During Deceleration

Possible Causes:

 * Low Idle Speed – Prevents the injection pump regulator from recovering quickly, causing shutdown.
 * Water Contamination in Fuel – Causes sticking in the metering valve or piston.

Solution: Use a lubricating additive; if ineffective, clean or replace the pump.

3. Diesel Generator Emits White Smoke

White smoke indicates unburned fuel particles exiting the exhaust (strong diesel smell).

Normal Cases:

Cold weather operation (before the engine warms up) 

Fault-Related Causes:

  • Cold Start Issues
  • Faulty glow plugs or control module
  • Low cranking speed / weak compression
  • Hot Engine Still Smoking
  • Faulty injector(s) (leaking or mistiming)
  • Worn injection pump
  • Clogged injectors (causing poor air-fuel mix, power loss, and white smoke)
  •  
  • Initial Diagnostic Step: Check the Battery!

Before deep troubleshooting, always verify the battery voltage. A weak or dead battery is a common reason for startup failure.

Conclusion

By systematically checking fuel supply, compression, injection timing, and electrical components, most diesel generator startup issues can be resolved efficiently. Regular maintenance ensures longevity and reliability when backup power is critical.

Perkins 1104C-44TAG2 Open Genset

Subscribe to Our Newsletter

Sign up for our monthly promotion and get out latest product news!

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Contact Us:nancy@ztapower.com

Home

Products

whatsapp

contact